BP100 Configuration Options
General Features
Feature Default
Pump 1 in Filter Cycle (Circ Only) No
Pump 1 Low Timer 30 Minutes Applies in non-circ Setups (configurations) only
General Pump Timer 15 Minutes
Blower Timer 15 Minutes
Mister Timer 15 Minutes
Light Timer 240 Minutes
Circ (when enabled) Programmable + Polling
Circ Pump can be set with the following functions:
24 hr – 24 hr w/3° shutoff – Acts like P1 Low (filters, polls, etc. - Requires a single-speed P1)
Cleanup Cycle 30 Minutes Between 30 and 240 minutes 30 Minutes
- or OFF
Cleanup as Preference setting Yes Yes, No N/A
Ozone With Heater Pump* Always, Filters/Cleanup Only N/A
Ozone Suppression OFF Between 30 and 120 min. 1 Minute
- or OFF
Pump Purge 60 Seconds Between 30 and 600 seconds 5 Seconds
Blower Purge 30 Seconds Between 5 and 300 seconds 5 Seconds
Mister Purge 5 Seconds
Purge Type Serial - Pumps at lowest speed
* The heater Pump can be either a Circ Pump or Pump 1 Low.