ML550, 551, 554
Panel Operation
Cool/Warm
ML500, 551, 554
Press the “Cool” or “Warm button once to display the set
temperature. Each time either button is pressed again, the
set temperature will increase or decrease depending on
which button is pressed. After three seconds, the LCD will
automatically display the last measured spa temperature.
Mode
ML500, 551, 554
This button is used to switch between Standard,
Economy, and Sleep modes. Press “Mode” to enter mode
programming, press Cool” to cycle through to desired
mode (LCD flashes until confirmed), then press Mode” to
confirm selection.
Sleep mode heats the spa to within 11°C (20°F) of the set
temperature only during filter cycles.
will appear on
the display until mode is changed.
Standby Mode
Pressing Cool” or “Warm” followed by Blower or “Jets 2”
or Aux” will turn off all spa functions temporarily. This is
helpful when changing a filter. Pressing any button exits
Standby mode. On some systems the Jets 1” button will
control the pump in Standby Mode (“Drain Mode”). In this
case, press any other button to exit. System will revert to
previous mode after 1 hour.
Jets 1
Press the “Jets 1” button once to turn pump 1 on or off, and
to shift between low and high speeds if equipped. If left
running, the pump will turn off after a time-out period. The
pump 1 low speed time-out on some systems may be as
long as 4 hours.
On non-circ systems, the low speed of pump 1 runs when
the blower or any other pump is on. It may also activate
for at least 1 minute every 30 minutes to detect the spa
temperature (polling) and then to heat to the set temperature
if needed, depending upon mode. When the low speed turns
on automatically, it cannot be deactivated from the panel;
however, the high speed may be started.
Jets 2
(optional on some systems)
Press the “Jets 2” button once to turn pump 2 on or off, and
to shift between low and high speeds if it is a two-speed
pump. If left running, the pump will turn off after a
time-out period.
Please refer to the following User Guides for more detailed information:
ML551/ML554 User Guide: P/N 40632-99
ML 550 User Guide: P/N 40569-99
ML551 ML554
HeatHeat
Warm
Light
Warm
Jets 1
Jets 2
Light
Mode
Cool
Blower
ML550
HeatHeat
Warm
Light
Warm
Jets 1
Jets 2
Light
Mode
Cool
Blower
Heat
Cool Warm Jets 1 Jets 2 Blower Light Mode

Table of Contents

Other manuals for Balboa ML551

Question and Answer IconNeed help?

Do you have a question about the Balboa ML551 and is the answer not in the manual?

Balboa ML551 Specifications

General IconGeneral
BrandBalboa
ModelML551
CategoryControl Panel
LanguageEnglish

Summary

ML550, 551, 554 Panel Operation

Cool/Warm Temperature Adjustment

Adjusting spa temperature using Cool and Warm buttons.

Mode Selection

Switching between Standard, Economy, and Sleep modes.

Standby Mode

Temporarily turning off spa functions for maintenance.

Jets 1 Operation

Controlling pump 1, including speed shifts and time-outs.

Jets 2 Operation

Controlling pump 2, including speed shifts and time-outs.

Blower Operation

Controlling the blower, including speed settings and time-outs.

Light Operation

Controlling the spa light, including dimming options.

Preset Filter Cycles

Programming automatic filter cycles for optimal spa operation.

Freeze Protection

Automatic activation of pumps/blower to prevent freezing.

Locking Features

Panel locking to prevent unintended changes.

Clean-up Cycle

Automatic cycle after pump/blower use for system cleaning.

Circ Pump Configuration

Options for continuous or intermittent circulator pump operation.

Ozone Generator Operation

Operation and suppression of the ozone generator.

Displaying Spa Information

Accessing system information like SSID and software version.

User Preferences Menu

Customizing spa settings like reminders and temperature units.

Dolphin II Address Setting

Configuring address for Dolphin II robotic cleaner integration.

Editing User Preferences

Step-by-step guide to changing user preference settings.

ML200, 240, 260, 400 Panel Operation

ML400 Introduction

Overview of the ML400 panel and its functions.

Initial Start-up and Priming

The initial boot-up sequence and priming mode.

Temperature Control

Displaying and adjusting the spa's set temperature.

Mode Selection (ML400)

Switching between Standard, Economy, and Sleep modes.

Standby Mode (ML400)

Temporarily disabling functions for maintenance.

Jets Operation (ML400)

Controlling pumps 1 and 2, including speed and time-outs.

Blower Operation (ML400)

Controlling the blower, especially with one pump.

Circ Pump Operation (ML400)

How the circulator pump functions in different configurations.

Light Operation (ML400)

Controlling the spa and fiber optic lights.

Ozone Operation (ML400)

Operation and suppression of the ozone generator.

Clean-up Cycle (ML400)

Automatic cleaning cycle following pump/blower use.

Freeze Protection (ML400)

System protection against freezing temperatures.

Locking Features (ML400)

Securing the panel to prevent unauthorized changes.

Preset Filter Cycles (ML400)

Programming filter cycles for system maintenance.

Displaying Spa Information (ML400)

Accessing technical data like SSID and software version.

User Preferences (ML400)

Customizing various spa operational settings.

Editing User Preferences (ML400)

Step-by-step process for modifying preference settings.

GL Series Mach 3 -- Persistent Memory & Power Up

About Persistent Memory

Understanding how settings are stored and retained.

Persistent Memory and Time of Day Retention

Differentiating memory storage for settings vs. time.

Power Up Display Sequence

Sequence of messages shown when the system powers on.

Configuration Error Messages (CFE)

Interpreting error codes related to configuration issues.

VL Series Panels -- For use with GS Systems

VL Panel Line-up

Overview of different VL series panel models.

GS Panel -- 500 Series and Operation

Initial Start-up and Priming

The initial boot-up sequence and priming mode.

Temperature Control

Displaying and adjusting the spa temperature.

Jets Operation (500 Series)

Controlling pumps 1, 2, and 3 (if applicable).

Light Operation (500 Series)

Activating and controlling the spa light.

Setting the Time of Day

How to set and confirm the current time.

Mode Selection (500 Series)

Switching between Standard, Economy, and Sleep modes.

Filter Cycles (500 Series)

Managing automatic filter cycles for system maintenance.

Optional Filter Cycle Programming (500DZ)

Advanced programming of filter cycle start/stop times.

Panel Locking (500DZ)

Methods to lock and unlock the control panel.

Temperature Locking (500DZ)

Methods to lock and unlock temperature adjustments.

Ozone Operation (500 Series)

Operation of the ozone generator during filtration.

GS Persistent Memory with VL Panels

Power Up Display Sequence

Visual indicators during system power-on.

Configuration Error Interpretation

Understanding error codes related to system configuration.

Changing a System Circuit Board

How to Remove a Circuit Board

Step-by-step instructions for removing the circuit board.

How to Replace a Circuit Board

Step-by-step instructions for installing a new circuit board.

Testing the Sensor Set

Removing the Heater Assembly from a Spa System

Panel Message Reference Guide

-- or --[ Message

Indicates temperature is not current in Economy or Sleep mode.

CFE Message

Signals a configuration error preventing spa startup.

CHANGE MINERAL CARTRIDGE Message

Reminder to replace the mineral cartridge.

CHECK PH Message

Prompt to test and adjust spa water pH levels.

CK SANITIZER Message

Prompt to test and adjust sanitizer levels.

CHKSUM FAIL Message

Indicates a firmware installation problem.

CLEAN COVER Message

Reminder to clean and condition the spa cover.

CLEAN FILTER Message

Prompt to remove, clean, and reinstall the spa filter.

CONFIG ERROR Message

Indicates incorrect system configuration.

C-C Message

Signals a firmware installation problem.

dr (ML Panels) Message

Inadequate water detected; check water level.

dr (VL panels) Message

Potential inadequate water or flow; reset manually.

DRAIN WATER Message

Reminder to drain and refill the spa.

DRAINING Message

Pump runs during Standby Mode to assist in draining.

drn Message

Inadequate water detected; spa shut down.

dy Message

Inadequate water detected; spa shut down, no auto-reset.

Ec / Ecn Economy Message

Spa operating in Economy Mode with specific display indicators.

FC Message

Indicates continuous filtration is active.

FREEZE COND Message

Potential freeze condition; pumps/blower activate.

GFCI FAILURE Message

Spa could not trip GFCI; operation may be unsafe.

HEATER DRY SERVICE ROI Message

Inadequate water detected; follow prior action.

HEATER MAY DE DRY WILL RETEST SHORTLY Message

Inadequate water detected; check water level.

HL / HFL / HTR FLOW LOW Message

Sensor difference indicates flow problem; check water level.

HH Message

"Overheat" condition; spa shut down. DO NOT ENTER WATER.

HOE Message

Pump stuck on; POWER DOWN SPA IMMEDIATELY.

HOT-CALL SVC Message

"Overheat" condition; spa shut down. DO NOT ENTER WATER.

HTR TEMP LMT Message

"Overheat" condition; spa shut down. DO NOT ENTER WATER.

ICE Message

Potential freeze condition; pumps/blower activate.

LF / LOW FLOW Message

Persistent low flow; heater shut down, other functions continue.

NEW FILTER Message

Reminder to install a new filter.

OH / OHS Message

"Overheat" condition; spa shut down, may reset at 107°F/41.7°C.

OHH Message

"Overheat" condition; spa shut down. DO NOT ENTER WATER.

PERSIST FAIL Message

Indicates a hardware failure; contact Balboa.

PH IS HIGH / LOWER PH Message

pH is high; add pH reducer.

PH IS LOW / RAISE PH Message

pH is low; add pH increaser.

Pr / PRIMING MODE TAKES 4 MIN Message

System entering Priming Mode upon initial actuation.

PSE Message

Indicates a hardware failure; contact Balboa.

rCA Message

Reminder to install a new mineral cartridge.

rCH Message

Reminder to install a new filter.

rCL Message

Prompt to remove, clean, and reinstall filter.

rCO Message

Reminder to clean and condition the spa cover.

rdr Message

Prompt to drain and refill the spa.

PH Message

Prompt to test and adjust pH chemical levels.

SA Message

Sanitizer level check reminder.

TEC Message

Indicates a hardware failure; contact Balboa.

RTC FAILURE Message

Prompt to test and reset RCD.

rES Message

Prompt to clean and condition wood components.

SA Message (Sensor A Fault)

Sensor A jack not working; test/replace sensor.

Sb Message (Sensor B Fault)

Sensor B jack not working; test/replace sensor.

SAH / SANITIZER HIGH Message

Sanitizer level is high; allow it to dissipate.

SAL / SANITIZER LOW Message

Sanitizer level is low; add sanitizer.

SbY Message (Standby Mode)

Standby Mode activated; press button to return to normal.

SE Message (Standard-in-Economy)

Operating in Standard-in-Economy mode, reverts to Economy.

SENSOR A SERVICE ROI Message

Sensor A not working; test and replace sensor.

SENSOR B SERVICE ROI Message

Sensor B not working; test and replace sensor.

SENSOR SYNC Message

Sensors out of balance; test and replace sensor.

SnA Message

Sensor A not working; test and replace sensor.

SnB Message

Sensor B not working; test and replace sensor.

SLP Message (Sleep Mode)

Sleep Mode activated; display shows "SLP".

SPA TEMP LMT Message

"Overheat" condition; spa shut down. DO NOT ENTER WATER.

STANDBY MODE Message

Standby Mode activated; press button to return to normal.

Sed Message (Standard Mode)

Spa operating in Standard Mode; temperature display is current.

SEU Message (Pump Stuck)

Pump stuck on; temperature rising. POWER DOWN IMMEDIATELY.

STUCK ON Message

Pump stuck on; temperature rising. POWER DOWN IMMEDIATELY.

TEST GFCI Message

Reminder to test and reset GFCI.

TREAT WOOL Message

Reminder to clean and condition wood components.