Ballu BSGI 12 - Sleep Mode Function; High Efficient Run Function (Invalid)

Ballu BSGI 12
51 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
6
.
.
C
C
O
O
N
N
T
T
R
R
O
O
L
L
M
M
O
O
D
D
E
E
L
L
receiving a signal from the remote controller. If the air conditioner has not received a signal
from the remote controller when the set time is up, it will turn off automatically.
6-3-3-3 Neither the turning on nor turning off operation will cancel the tim
er function (Some
remote controller has a simple one-hour timer off function and excludes this operation).
6-3-4 Sleep
6-3-4-1 In the heating, cooling or dehumidifying mo
de, press the “Sleep” button on the remote
controller to start or cancel the sleep function in turn, and at the same time the sleep icon on
the display screen will be on or off accordingly.
6-3-4-2 According to the different needs, there are four dif
ferent sleep modes to choose.
During the time of sleep mode, the set temperature will change automatically.
6-3-4-3 In default, the setting is to cancel the sleep function. Turning off the unit will also
cancel the sleep function.
6-3-4-4 The sleep function is valid for 8 hours. The air condition
er will turns off and cancel the
sleep function after the sleep function works for 8 hours.
6-3-5 High efficient run function (This function is invalid)
In the heating (except for the single cooling unit), cooling o
r dehumidifying mode, it may be set
for high efficient run with the indoor fan speed changed to the high efficient fan speed and the
compressor operating at the highest frequency as available. If the display screen can display
the frequency, the frequency displayed on the screen is up to the maximum. It will restore to
the previous run state after 15 minutes operation automatically.
6-3-6 Automatic run (SMART) mode
If there is no man-machine communication function af
ter the unit is started, the indoor fan
operates at the ultra-low flowrate for 20 seconds before selecting a run mode; the room
temperatures are detected during this period for the selection of a run mode.
In the first operation:
a. When
T
room
– T
set
3 it starts in the cooling mode;
b.
When -3T
room
– T
set
3 it starts in the ventilation run mode;
c. When
T
room
– T
set
-3, it starts in the heating mode.
After the first run in the cooling or heating mode, the mode will be changed as the following:
20