a. When T
room
– T
set
>3℃, it will be changed to the cooling mode;
b. When
T
room
– T
set
<-3℃, it will be changed to the heating mode;
c.
When these conditions are not met, it will remain in the previous run mode.
When the temperature setting is changed, re-judgment will be made
for the run mode
according to the descriptions mentioned above; when the compressor is halted for 10 minutes,
the re-judgment will be made for the run mode.
6-3-6-1 Switch between the cooling a
nd heating mode:
T
ambient
t
set
+3
t
set
t
set
-3
Coolin
mode Cooling
6-3-6-2 Cooling→heating turnover
operation
Cooling→h
eating: the compressor stops; 50 s later the 4-way valve is activated and 3 minutes
more the compressor turns on.
Heating→co
oling: the compressor stops, 50 s later the 4-way valve is interrupted and 3
minutes more the compressor turns on.
6-3-6-3 There is temperature compensation during the auto-run, which is same as cooling and
heating.
6-3-7 Cooling-run mode
6-3-7-1 Temperature compensation
Principle for compensation: The compensation is available o
nly if the proper sensor is used
and it is not available when it is subject to the sensor on the remote controller.
6-3-7-2 Outdoor Fan
The outdoor fan’s speeds are divided into two levels which can be changed over according to
out
door ambient temperatures.
When operating at a fixed frequency, the outdoor fan is forced to operate at the high speed.
6-3-7-3 Indoor fan
When the fan speed is set at the high, medium a
nd low fan speeds, the fan runs at a preset
speed. When the fan speed setting is automatic, the fan speed is set based on the difference
in room temperatures.