EasyManua.ls Logo

Banner EZ-SCREEN LP - Page 14

Banner EZ-SCREEN LP
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Overview
EZ-SCREEN LP
Instruction Manual
Components and Specifications
Components and Specifications
Muting Modules
Provide muting capability for the EZ-SCREEN LP. See Banner manuals p/n 63517 or 116390
for further information and additional cabling options.
MMD-TA-11B
DIN-mount
Muting module
2 NO safety outputs (6 amps), 2 or 4 muting inputs, SSI,
override input; IP20; terminal connections
MMD-TA-12B
2 OSSD (0.5 amps), 2 or 4 muting inputs, SSI, override input;
IP20; terminal connections
MM-TA-12B Muting module
2 OSSD (0.5 amps), 2 or 4 muting inputs, USSI, override
input; IP65; QD connections, see below
DESE4-508D
DESE4-515D
DESE4-525D
2.5 m (8’) cable
5 m (15’) cable
8 m (25’) cable
Cordset to interface EZ-SCREEN LP Receiver with MM-TA-
12B Muting Module – 22 Ga, 8-pin Euro-style (M12) female
connector to 7-pin Mini-style male connector; double-ended.
NOTE:DELPE-8..D cordsets required on RD-interconnect
sensor models, or DEE2R-8..D cordsets on pigtail
interconnect models.
SC22-3(E) Safety Controller
Provide monitoring of multiple safety devices via 22 configurable inputs to control three
pairs of OSSD safety outputs. Other options available (e.g., EtherNet communications); see
Banner manual p/n 133487.
SC22-3-S Screw-type terminals
10 Auxiliary outputs, includes external memory XM
card
SC22-3-C Clamp-type terminals
SC22-3E-S Screw-type terminals
10 Auxiliary outputs, includes external memory XM
card, plus EtherNet/IP and Modbus TCP, 32 virtual
outputs
SC22-3E-C Clamp-type terminals
Remote Blanking Key Switch Box
Used to configure fixed blanking remotely on cascadeable model receivers (when used as a
standalone sensor pair, or the last receiver in a cascade). Use with DELPEF-8..D cordset to
interface with receiver cascade end and DEE2R-8..D cordset to provide required extension,
as needed.
EZA-RBK-1
Remote Blanking Key
Switch
Allows the frequent configuration of a fixed blanked
area, without using the receiver DIP switches
External Keyed Reset Switches
EZA-RR-1
External normally open reset switch with 8-pin M12/Euro-style QD;
can be
interconnected using cordset models QDE-8..D, DEE2R-8..D, or
CSB-..M1281.
MGA-KSO-1 Panel-mount keyed normally open reset switch
MGA-K-1 Replacement key for switch MGA-KSO-1
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com