EasyManua.ls Logo

Banner EZ-SCREEN LP - 7.4 Determining Interconnect Cordset Lengths

Banner EZ-SCREEN LP
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Overview
EZ-SCREEN LP
Instruction Manual
Cascadeable EZ-SCREEN
7.4 Determining Interconnect Cordset Lengths
The following Cordset length charts are possible combinations
for each side of example cascaded systems. Model DELP-..E
cordsets (24 awg wire) used for calculations. Other lengths and
combinations are possible; please call factory for assistance.
As the machine interface Cordset lengthens, the voltage drop
Machine Interface Cordset (L1)
QDE-8..D or RDLP-8..D
0.9 m (3') 4.6 m (15') 7.6 m (25') 15.2 m (50')
Example Cordset pairing per side of cascaded system
Sensor
Interconnect
Cordset Lengths
(L2)
Max. L2* 58.2 m (191') 47.5 m (156') 38.4 m (126') 16.2 m (53')
Individual
DELP-11..E Cordsets
30.5 m (100') 30.5 m (100’) 30.5 m (100')
22.9 m (75') 22.9 m (75') 22.9 m (75')
15.2 m (50') 15.2 m (50') 15.2 m (50') 15.2 m (50')
7.6 m (25') 7.6 m (25') 7.6 m (25') 7.6 m (25')
4.6 m (15') 4.6 m (15') 4.6 m (15') 4.6 m (15')
2.4 m (8') 2.4 m (8') 2.4 m (8') 2.4 m (8')
0.9 m (3') 0.9 m (3') 0.9 m (3') 0.9 m (3')
0.3 m (1') 0.3 m (1') 0.3 m (1') 0.3 m (1')
0.1 m (0.33') 0.1 m (0.33') 0.1 m (0.33') 0.1 m (0.33')
Example 1: Example 2:
Machine Interface Cordset (L1): 4.6 m (15') Machine Interface Cordset (L1): 15.2 m (50')
Sensor Interconnect Cordset (L2): 45.7 m (150'), using one 30.5 m (100') and Sensor Interconnect Cordset (L2): 15.2 m (50') or shorter
one 15.2 m (50') DELP..-.. cordset, or 30.5 m (100') or shorter using single cordsets
Figure 7-2. Cordset length options for two cascaded light screens
Figure 7-3. Cordset length options for three cascaded light screens
increases, which results in shorter possible interconnect Cordsets
to maintain supply voltage requirements at the cascaded sensor.
See Section 2 for Cordsets.Due to the large number of possible
combinations, the table in Figure 7-4 includes only applications
in which L2 = L4. A common installation example is one that
protects two areas of a machine (e.g., the front and back of a
power press) and uses four EZ-SCREEN LP pairs to create two
“L”-shaped sensing fields.
Example 1: Example 2:
Machine Interface Cordset (L1): 0.9 m (3') Machine Interface Cordset (L1): 4.6 m (15')
Sensor Interconnect Cordset (L2): 22.9 m (75') Sensor Interconnect Cordset (L2): 7.6 m (25')
Sensor Interconnect Cordset (L3): 7.6 m (25') or shorter Sensor Interconnect Cordset (L3): 22.9 m (75') or shorter
*Multiple DELP..-.. cordsets may be required.
*Multiple DELP..-.. cordsets may be required.
Machine Interface Cordset
(L1) QDE-8..D or RDLP-8..D
0.9 m (3') 4.6 m (15') 7.6 m (25') 15.2 m (50')
Example Cordset pairing per side of cascaded system
Sensor
Interconnect
Cordset
Lengths (L2, L3)
L2 L3 L2 L3 L2 L3 L2 L3
Max. L2*
28.7 m
(94')
0.3 m
(1')
22.3 m
(73')
0.3 m
(1')
16.8 m
(55')
0.3 m
(1')
3 m
(10')
0.3 m
(1')
Max. L3*
0.3 m
(1')
57.0 m
(187')
0.3 m
(1')
43.9 m
(144')
0.3 m
(1')
32.9 m
(108')
0.3 m
(1')
5.8 m
(19')
Individual
DELP-11..E Cordsets
22.9 m (75') 7.6 m (25')
15.2 m (50') 22.9 m (75') 15.2 m (50') 15.2 m (50') 15.2 m (50') 2.4 m (8')
7.6 m (25') 30.5 m (100') 7.6 m (25') 22.9 m (75') 7.6 m (25') 15.2 m (50')
4.6 m (15') 30.5 m (100') 4.6 m (15') 30.5 m (100') 4.6 m (15') 22.9 m (75')
2.4 m (8') 30.5 m (100') 2.4 m (8') 30.5 m (100') 2.4 m (8') 22.9 m (75') 2.4 m (8') 0.9 m (3')
0.9 m (3') 30.5 m (100') 0.9 m (3') 30.5 m (100') 0.9 m (3') 30.5 m (100') 0.9 m (3') 4.6 m (15')
0.3 m (1') 30.5 m (100') 0.3 m (1') 30.5 m (100') 0.3 m (1') 30.5 m (100') 0.3 m (1') 4.6 m (15')
0.1 m (0.33') 30.5 m (100') 0.1 m (0.33') 30.5 m (100') 0.1 m (0.33') 30.5 m (100') 0.1 m (0.33') 4.6 m (15')
L2
L1
EZ-SCREEN
LP Position
#2
Emitters
Machine
Control
Receivers
L3
EZ-SCREEN
LP Position
#1
EZ-SCREEN
LP Position
#3
L2
L1
EZ-SCREEN
LP Position
#2
Emitters
Machine
Control
Receivers
EZ-SCREEN
LP Position
#1
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com