EasyManua.ls Logo

Banner EZ-SCREEN LP - Page 42

Banner EZ-SCREEN LP
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Overview
EZ-SCREEN LP
Instruction Manual
Installation and Alignment
Figure 3-24. Generic hookup – FSDs (2-channel EDM, manual reset)
+24V dc 0V dc
Receiver
8-pin male
Euro-style
face view
Bn (Pin #1)
Gn/Ye (#7)
Bu (#6)
Bk (#5)
Wh (#4)
Vi (#8)
Or (#3)
Or/Bk (#2)
+24V dc
Ground
0V dc
OSSD1
OSSD2
Reset*
EDM1
EDM2
FSD
2
FSD
1
Single-Channel
Safety Stop
Circuit
Dual-Channel
Safety Stop
Circuit
NOTE: Do not exceed OSSD maximum load
capacitance specification.
*Trip (auto reset) – Not connected
See Table 2.2 for further
QDE-8..D cable information.
Figure 3-25. Generic hookup – self-checking Safety module, Safety Controller, Safety PLC (no monitoring, automatic reset)
+24V dc 0V dc
Receiver
8-pin male
Euro-style
face view
Bn (Pin #1)
Gn/Ye (#7)
Bu (#6)
Bk (#5)
Wh (#4)
Vi (#8)
Or (#3)
Or/Bk (#2)
Jumper
+24V dc
Ground
0V dc
OSSD1
OSSD2
Reset*
EDM1
EDM2
*Trip (auto reset) – Not connected
See Table 2.2 for further
QDE-8..D cable information.
S1
A1 A1 A2 A2
S2S3
SC22-3
Safety Controller
NOTE: EZ-SCREEN LP receiver DIP switches are
configured for “Trip” (T) output and 2-channel
EDM. If the Auxiliary output is to be used,
configure the EZ-SCREEN LP receiver for
1-channel EDM and connect pin #3 (Or) to
+24V dc.
See Section 2.3 for further
cordset information.
See Section 2.3 for further
cordset information.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com