What to do if the compressor won't start on my Bard W42HC-A Heat Pump?
- EEmily DelgadoAug 12, 2025
If the compressor of your Bard Heat Pump isn't starting, there could be several reasons. First, wait for the 5-minute delay or try jumping the board's "speed up pins". It could also be due to a low or high pressure fault, in which case you should check the wiring circuit and unit pressures. Another possibility is no power to the board, meaning the unit lacks voltage, the transformer is faulty, or the wiring is incorrect. If there's no "Y" compressor input signal, inspect the thermostat and unit wiring, and check the unit's phase. If there's no "CC" compressor output signal, check the compressor contactor and the compressor itself. Lastly, a faulty board could be the issue, requiring a replacement of the defrost board.