Bard WH Series User Manual

Bard WH Series
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Form No. S3210-206
Supersedes S3210-106
Page 1 of 12
Engineered Features
THE WALL-MOUNT
TM
HEAT PUMPS - WH (60HZ)
Aluminum Finned Copper Coils:
Grooved tubing and enhanced louvered
fin for maximum heat transfer and
energy efficiency.
Twin Blowers:
Move air quietly. Most models feature
multispeed blower motors providing
airflow adjustment for high and low static
operation. Motor overload protection is
standard on all models.
Heat Pump Compressor:
Reciprocating compressor designed to
withstand higher compressor ratios and
longer operation than normal air
conditioning compressors. Equipped
with crankcase heater and dual
discharge muffler. Standard on all 2, 2½,
3 and 3½ ton models.
Scroll compressor designed for
increased efficiency, quieter operation
and improved reliability for longer life.
Eliminates need for crankcase heater
and suction accumulator. Standard on
all 1½, 4 and 5 ton models.
Galvanized 20 Gauge Zinc Coated
Steel Cabinet:
Cleaned, rinsed, sealed and dried
before the polyurethane primer is
applied. The cabinet is handsomely
finished with a baked on, beige textured
enamel, which allows it to withstand
1000 hours of salt spray tests per ASTM
B117-03.
Electrical Components:
Are easily accessible for routine
inspection and maintenance through a
right side, service panel opening.
Features a lockable, hinged access
cover to the circuit breaker or pull
disconnect switch.
Electric Heat Strips:
Features an automatic limit and thermal
cut-off safety control. Heater packages
are factory or field installed for all 1½
through 5 ton models. Features easy
slide-in field assembly with various
BTUH outputs.
Condenser Fan and Motor
Shroud Assembly:
Slide out for easy access.
One Inch, Disposable Air Filters:
Are standard equipment. Optional one
inch washable filters available and
filter racks permit the addition of 2"
pleated filter. Factory or field installed.
Solid State Electronic Heat Pump
Control:
Provides efficient 30, 60 or 90 minute
defrost cycle. A thermistor sensor,
speed up terminal for service and 10
minute defrost override are standard on
the electronic heat pump control.
High Pressure Switch:
Is built-in with a lockout circuit that
resets from the room thermostat.
Five Minute Compressor Time
Delay:
Short cycle protection is standard. Built
into the heat pump control.
Suction Accumulator:
Protects the reciprocating compressor
from refrigerant flood back and prevents
damage to the compressor bearing
surfaces. Not required on scroll
compressor applications.
Emergency Heat Circuit:
Permits continuous operation of the
system.
Barometric Fresh Air Damper:
Standard on all units. Allows up to 25%
outside fresh air.
Built-in Circuit Breakers:
Standard on all electric heat versions of
single and three phase (230/208 volt)
equipment. Toggle disconnects are
standard on all electric heat versions of
three phase (460 volt) equipment.
Slope Top:
Standard feature for water run-off.
Full Length Mounting Brackets:
Built into cabinet for improved
appearance and easy installation.
NOTE: Bottom mounting bracket
included to assist in installation.
Top Rain Flashing:
Standard feature on all models.
Ventilation System Packages
All packages are designed
to meet your specific
ventilation requirements
utilizing one of six
ventilation options for the
product. The ventilation
package is mounted within
the unit eliminating the
need for an exterior
mounted hood or damper
assembly on the unit. All
assemblies can be factory
installed, installed in the
field at time of installation
or as a retrofit system after
installation.
Standard - Barometric
Fresh Air Damper
Optional - Motorized
Fresh Air Damper
Optional - Blank off Plate
Optional - Commercial
Room Ventilator w/Exhaust
• CRV - Spring Return
• CRVP - Power Return
Optional - Economizer
with Exhaust
Optional - Energy
Recovery Ventilator
The Bard Wall-Mount Heat Pump is a self-contained energy efficient heating and
cooling system, which is designed to offer maximum indoor comfort at a minimal
cost without using valuable indoor floor space or outside ground space. This unit is
the ideal product for versatile applications such as: new construction, modular
offices, school modernization, telecommunication structures, portable structures or
correctional facilities. Factory or field installed accessories are available to meet
specific job requirements.
Complies with efficiency requirements of ASHRAE/IESNA 90.1-2004.
Certified to ARI Standard 390-2003 for SPVU (Single Package Vertical Units).
Commercial Product - Not intended for Residential application.
WH-Series Refrigerant 22 60Hz
Heating Capacities: 18,800 to 58,000 BTUH
Cooling Capacities: 19,000 to 56,500 BTUH
Question and Answer IconNeed help?

Do you have a question about the Bard WH Series and is the answer not in the manual?

Bard WH Series Specifications

General IconGeneral
BrandBard
ModelWH Series
CategoryHeat Pump
LanguageEnglish

Summary

Engineered Features

Aluminum Finned Copper Coils

Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency.

Twin Blowers

Multispeed blower motors for airflow adjustment; motor overload protection is standard.

Heat Pump Compressor

Reciprocating or scroll compressor designed for higher ratios and longer operation.

Galvanized Steel Cabinet

20 gauge zinc-coated steel cabinet finished with baked-on enamel for durability.

Electrical Components

Accessible through a right side service panel with lockable access cover.

Electric Heat Strips

Features automatic limit and thermal cut-off safety control; field installed.

Condenser Fan and Motor Shroud Assembly

Assembly slides out for easy access.

Air Filters

Standard 1-inch disposable filters; optional washable filters available.

Electronic Heat Pump Control

Provides efficient defrost cycles with thermistor sensor and override.

High Pressure Switch

Built-in lockout circuit that resets from the room thermostat.

Compressor Time Delay

Short cycle protection is standard and built into the heat pump control.

Suction Accumulator

Protects reciprocating compressor from refrigerant flood back.

Emergency Heat Circuit

Permits continuous operation of the system.

Barometric Fresh Air Damper

Standard on all units, allows up to 25% outside fresh air.

Built-in Circuit Breakers

Standard on electric heat versions; toggle disconnects on 460V.

Slope Top

Standard feature for water run-off.

Mounting Brackets

Full length brackets built into cabinet for improved appearance.

Top Rain Flashing

Standard feature on all models.

Ventilation System Packages

Barometric Fresh Air Damper (BFAD)

Standard feature; allows up to 25% outside air, mixed with conditioned air.

Blank Off Plate (BOP)

Optional; covers air inlet openings, restricts outside air entry.

Motorized Fresh Air Damper (MFAD)

Optional; internally mounted, allows outside air, controlled by 24VAC motor.

Commercial Room Ventilator (CRV)

Optional; allows up to 50% outside air, includes exhaust air damper.

Economizer (EIFM)

Optional; provides "free cooling" when outside air is cool and dry.

Energy Recovery Ventilator (WERV)

Optional; meets IAQ requirements, provides heat transfer.

WERV-2B Performance Data

Summer Cooling Performance

Cooling performance data for WERV-2B at various ventilation rates and ambient conditions.

Winter Heating Performance

Heating performance data for WERV-2B at various ventilation rates and ambient conditions.

WERV-3C Performance Data

Summer Cooling Performance

Cooling performance data for WERV-3C at various ventilation rates and ambient conditions.

Winter Heating Performance

Heating performance data for WERV-3C at various ventilation rates and ambient conditions.

WERV-5C Performance Data

Summer Cooling Performance

Cooling performance data for WERV-5C at various ventilation rates and ambient conditions.

Winter Heating Performance

Heating performance data for WERV-5C at various ventilation rates and ambient conditions.

Service Access and Condenser Airflow Clearances

Required Service Clearances

Minimum clearances for service access on left and right sides of the unit.

Combustible Material Clearances

Minimum clearances required to combustible materials for supply air duct and cabinet.

Unit Dimensions and Installation Requirements

Basic Unit Dimensions

Nominal dimensions for unit width, depth, height, and port locations (A-T).

Electrical Specifications

Single Circuit Electrical Requirements

Details on single-circuit power, ampacity, fuses, and wire size.

Dual Circuit Electrical Requirements

Details on dual-circuit power, ampacity, fuses, and wire size.

Electrical Specification Notes

Important notes on wire sizing, derating, and compliance with codes.

Blower and Electric Heat Specifications

Indoor Blower Performance Data

CFM data for indoor blowers at various ESP and voltage conditions.

Electric Heat Availability

Lists available electric heat KW, voltage, and Btuh ratings by unit model.

Field Installed Heater Packages

Part numbers and KW for field-installable electric heater packages.

Cooling and Heating Performance Tables

Cooling Capacity Data

Cooling capacity data at various ambient DB/WB and indoor conditions.

Heating Application Data

BTUH, COP, and HSPF ratings across different temperatures and applications.

Model Nomenclature and Options

Model Number Configuration

Explanation of each component in the unit model number designation.

Ventilation Options Selection

Table detailing available factory and field installed ventilation options.

Heat Pump Control Modules

Overview of available control modules for low pressure and low ambient control.

Related product manuals