MODEL
NO
HP VOLT PH Hz
RPM
(Nom)
NEMA
START
CODE
FULL
LOAD
AMPS
1.2 SERVICE
FACTOR
AMPS
LOCKED
ROTOR
AMPS
CORD
P/N
CORD
SIZE
CORD
O.D.
WINDING
RESISTANCE
MAIN - - START
4SHVA Pump
4SHVA75N2 7.5
208
3 60 3450 M
24.2 28.0
173.9 / 201.0
125496 12/4 - 18/4 .86 ± .02 0.40
230 25.4 28.2 125496 12/4 - 18/4 .86 ± .02 0.40
460 12.7 14.1 100.5 125497 12/4 - 18/4 .86 ± .02 1.58
4SHVA7552 7.5 575 3 60 3450 M 10.2 11.3 80.4 125497 12/4 - 18/4 .86 ± .02 2.47
4SHVA100N2 10.0
208
3 60 3450 K
30.8 37.0
173.9 / 201.0
125498 8/4 - 18/4 1.12 ± .02 0.40
230 30.1 34.8 125498 8/4 - 18/4 1.12 ± .02 0.40
460 15.1 17.4 100.5 125497 12/4 - 18/4 .86 ± .02 1.58
4SHVA10052 10.0 575 3 60 3450 K 12.1 13.9 80.4 125497 12/4 - 18/4 .86 ± .02 2.47
4SHVA2074 2.0
208
1 60 1750
G 10.4 12.1 59.1 125496 12/4 - 18/4 .86 ± .02 0.88 - 2.14
230 J 10.7 11.9 66.3 125496 12/4 - 18/4 .86 ± .02 0.88 - 2.14
4SHVA20N4 2.0
208
3 60 1750 P
7.4 8.3 58.2 125496 12/4 - 18/4 .86 ± .02 1.08
230 7.4 8.0 65.8 125496 12/4 - 18/4 .86 ± .02 1.08
460 3.7 4.0 32.9 125497 12/4 - 18/4 .86 ± .02 4.32
4SHVA2054 2.0 575 3 60 1750 T 3.9 4.2 37.0 125497 12/4 - 18/4 .86 ± .02 4.32
4SHVA3074 3.0
208
1 60 1750
D 14.9 118.5 59.1 125496 12/4 - 18/4 .86 ± .02 0.88 - 2.14
230 F 14.1 16.5 66.3 125496 12/4 - 18/4 .86 ± .02 0.88 - 2.14
4SHVA30N4 3.0
208
3 60 1750 K
9.7 11.4 58.2 125496 12/4 - 18/4 .86 ± .02 1.08
230 9.2 10.6 65.8 125496 12/4 - 18/4 .86 ± .02 1.08
460 4.6 5.3 32.9 125497 12/4 - 18/4 .86 ± .02 4.32
4SHVA3054 3.0 575 3 60 1750 N 4.5 4.9 37.0 125497 12/4 - 18/4 .86 ± .02 4.32
4SHVA5074 5.0
208
1 60 1750
D 27.2 35.6 99.9 125498 8/4 - 18/4 1.12 ± .02 0.50 - - 2.66
230 F 25.4 30.2 112.4 125496 12/4 - 18/4 .86 ± .02 0.50 - - 2.66
4SHVA50N4 5.0
208
3 60 1750 J
15.8 18.7 82.4 125496 12/4 - 18/4 .86 ± .02 0.72
230 15.0 17.2 92.4 125496 12/4 - 18/4 .86 ± .02 0.72
460 7.5 8.6 46.2 125497 12/4 - 18/4 .86 ± .02 2.88
4SHVA5054 5.0 575 3 60 1750 J 6.0 6.9 37.0 125497 12/4 - 18/4 .86 ± .02 4.32
Moisture and Temperature sensor leads are integral to power cord.
Winding Resistance ± 7.5% Winding resistance measured in OHMS @ 25°C (Between Lines) at motor leads.
Pump rated for operation at ± 10% voltage at motor.
▲ Cord Sufx: XC - 30 Feet, XF - 50 Feet, XJ - 75 Feet, or XL - 100 Feet
▲ Cord sold separately.
Single Phase pumps require start components to be included in panel. Provided with pump.