Cone Fire, Vary-Fire, Delay Start, Preheat, and Alarm functionalities.
Cone Offset, Skip Step, Error Codes, and 16 Segment Programs.
Review Program, View Segment, and Cone Table functions.
General safety, static electricity, probe placement, and program review.
Start-Stop, Vary-Fire, Options, Cone Fire, and View sections.
LED Display and Number Keys for operations.
How the controller manages temperature and power using set-points.
Explains Cone fire and Vary-fire programming modes.
Precautions, kiln setup, programming notes, and mode overview.
How to return to idle and save firing time after completion.
Steps to select speed, enter cone number, and set hold time for Cone Fire.
How to enable and program a preheat stage for Cone Fire modes.
Step-by-step guide for a Slow Bisque Cone Fire with preheat and hold.
How to program up to 8 segments for custom firing profiles.
Example of a two-segment program for Vary-Fire.
How to recall a previously programmed firing profile.
Navigate and view program details like cone temps and segments.
Used to look up the temperature of various cone numbers.
Displays firing profile steps for Cone Fire or Vary Fire modes.
Monitor current segment or skip to next ramp during firing.
Used to delay the start of a firing.
Used to set the high or low temperature alarm.
Accesses functions like reset, preheat, cone offset, etc.
Example of setting a 2-hour preheat time.
ID for KISS software and 16-S segment program setup.
Used to raise or lower the final cone temperature.
Used to raise or lower the temperature indicated by thermocouples.
Selects between Fahrenheit (°F) and Celsius (°C).
Used to turn on or turn off error codes for protection.
Displays circuit board temperature for diagnostics.
3 zones, offsets, lag, continuing with failed t/cs, general description.
Setting lag and adjusting thermocouple readings for zone control.
Allows firing to continue if one or two thermocouples fail.
Zone error checking, turning errors off, and accessing Other menu options.
Specifics for Slow Bisque, Slow Glaze, Fast Bisque, Fast Glaze profiles.
Details error codes Err0 to Err4 and their meanings.
Details error codes Err5 through FAIL and their causes.
Correcting errors, clearing display messages, and finding final temp.