14-6 9469200995
Exhaust Treatment DGC-2020ES
Exit Conditions for DEF Severe Inducement
First Restart: Return to 0% torque reduction in exit condition, until proper DEF level and quality
evaluation. If low level or poor DEF quality is detected during the next monitoring cycle, the severe
inducement will be active after the next restart. After the second restart, a service tool is required to
exit the severe inducement.
With Service Tool Clearing: Invoke 0% torque reduction with service tool clearing until proper DEF
level and quality evaluation. If low level or poor DEF quality is detected during the next monitoring
cycle, the severe inducement will be active after the next restart.