EasyManua.ls Logo

Bauer Compressors MAXI VERTICUS - 4.2 P5 Purification System; 4.2.1 Component Description

Bauer Compressors MAXI VERTICUS
113 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MNL- 0345
Page 78 Section 4 Base Edition
4.2 P5 Purification System
4.2.1 Component Description
The P5Purification System major components are a Coalescing Oil and Water Separator, a Dryer Cham-
ber and a Purification Chamber. Figure 4.2-1 shows the functional interconnection of all the components.
TheP2 purification system is available with the Securus Moisture Monitoring System as a factory
installed option. As part of this option the Purification Chamber is replaced with a Securus
®
Purification
Chamber.
4.2.1.1 Chamber
Each chamber is made up of an anodized aluminum alloy filter housing and a filtering cartridge. There
are two general types of filtering cartridges, drying or purifying. The cartridge type is determined by the
ingredients packed in the cartridge. The chamber is named after the type of cartridge it contains, i.e. dryer
chamber or purification chamber.
Figure 4.2-1 P5 Purification System
1. Coalescing Oil/Water Separator
2. Condensate Drain Valve
3. Check Valves
4. Dryer Chamber
5. Purification Chamber
6. Bleed Valve
7. Pressure Maintaining
Val ve
8. Safety Valve
OUT
IN
7
3
8
1
2
3
4
5
6

Table of Contents

Related product manuals