  • W
    whiteheadrobertAug 11, 2025
    What to do if the red error LED is lighting up on Baumuller Control Unit?
    • J
      Jennifer BlankenshipAug 11, 2025
      If the red error LED is illuminated, it indicates an error. You can address this in several ways: * Using ProDrive (from FW 3.07), click the “Quit errors” button in the “Device manager” dialog box or on the “Device manager” page to acknowledge and address the error. * By writing access to control word (P0300), generate a rising edge in bit 7. * Configure a digital input of a DIO module via parameter P0575 for error reset. * Use the pulse enable input, assuming the drive is controlled solely via hardware inputs.
  • J
    jonathan15Aug 15, 2025
    How to start the motor on Baumuller Control Unit if the red LED H4 isn’t lighting up and the LED H2 is green?
    • S
      Stephanie HarringtonAug 15, 2025
      If the motor doesn't start, but the red LED H4 is off and the LED H2 is green, check the parameterization of the b maXX 4000 using the parameter list in ProDrive. Possible errors include a torque limit set to 0 or an incorrect notch position.
  • S
    Susan HodgesAug 21, 2025
    What to do if no LEDs are lighting up on the front side of the Baumuller Control Unit?
    • S
      sethcollinsAug 21, 2025
      If no LEDs are lit on the front of the device, verify the 24V supply.
  • B
    brian40Aug 26, 2025
    What to do if Baumuller DC Drives show Watchdog-Error?
    • A
      Adam JonesAug 26, 2025
      If you encounter a Watchdog-Error with your Baumuller DC Drives, execute a restart of b maXX® 4400.
  • J
    joeandersonAug 30, 2025
    What to do if an incorrect interrupt has occurred in Baumuller DC Drives?
    • V
      vegamichelleAug 30, 2025
      If an incorrect or unexpected interrupt has occurred with your Baumuller DC Drives, execute a restart of b maXX® 4400.
  • R
    Robert WilsonSep 4, 2025
    What to do if NMI interrupt or bus error appear in Baumuller DC Drives?
    • R
      rebecca50Sep 4, 2025
      If you are experiencing an NMI interrupt or bus error with your Baumuller DC Drives, execute a restart of b maXX® 4400.

Baumuller b maXX BM4 Series Specifications

General IconGeneral
Seriesb maXX BM4
TypeDC Drives
Enclosure RatingIP20
CommunicationCANopen
Protection FeaturesOvercurrent, overtemperature, short circuit
Relative HumidityUp to 95% (non-condensing)
CoolingAir or liquid cooling