0x05040000 SDO protocol timed out.
0x05040001 Unknown command ID
0x05040002 Invalid block size
0x05040003 Invalid sequence number
0x05040005 Out of memory
0x06010000 Unsupported access to an object
0x06010001 Attempt to read a write-only object
0x06010002 Attempt to write a read-only object
0x06020000 Object does not exist in the object dictionary
0x06040041 Object cannot be mapped to the PDO.
0x06040042 The number and length of the objects to be mapped would exceed PDO
length
0x06040043 General parameter incompatibility
0x06040044 Invalid heartbeat declaration
0x06040047 General internal incompatibility in the device
0x06060000 Access failed due to an hardware error
0x06070010 Data type does not match, length of service parameter does not match
0x06070012 Data type does not match, length of service parameter too high
0x06070013 Data type does not match, length of service parameter too low
0x06090011 Sub-index does not exist
0x06090030 Value range of parameter exceeded (only for write access)
0x06090031 Value of parameter written too high
0x06090032 Value of parameter written too low
0x06090036 Maximum value is less than minimum value
0x08000000 General error
0x08000020 Data cannot be transferred or stored to the application.
0x08000021 Data cannot be transferred or stored to the application because of local
control
0x08000022 Data cannot be transferred or stored to the application because of the
present device state.
0x08000023 Object dictionary is not available
0x08000024 Configuration data set is empty
Data Exchange and Parameterization
Application Manual POWERLINK Controlled Node
Document no. 5.13013.04
35
of 80
5
Abort code Description