EasyManua.ls Logo

Baumuller BM5300 Series - Page 182

Baumuller BM5300 Series
330 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connections on the front side
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
182
of 328
7.15
POWERLINK
®
Type code b maXX 5000 with POWERLINK
®
:
BM5XXX-XXXX-XXXX-04XX
X3
X4
POWERLINK
®
IN
POWERLINK
®
OUT
Number of bus connections 1 IN / 1 OUT
Bus connection RJ 45
Number of parameters refer to
p
arameter handbook b maXX 5000
Data size of parameters 16 / 32 Bit
Baud rates 10 / 100 Mbit/s
X3
X4
1: TX+
2: TX-
3: RX+
4: re
served
5: re
served
6: RX-
7: re
served
8: re
served
Add-on modules
NOTE!
Only devices with type code BM5XXX-XXXX-XX01/03/04/05/06 provide an add-on
module!
The add-on modules are built-in and cannot be changed.
It is forbidden to remove the yellow front cover.

Table of Contents