Design and Operation
Instruction handbook b maXX 5000
Document No.: 5.09021.16
93
of 328
4
4.4.2.1 7-segment display BM51XX
Refer to parameter manual for detailed description of drive states and state transitions.
0: Low, 1: High
Display
0
NOT READY TO SWITCH ON Device message „Not ready for switching power on“
1
SWITCH-ON INHIBIT Device disabled
2
READY TO SWITCH ON Device shutdown
Control word: xxxx x110
Pulse enable = 0
Quick discharge = 0
3
SWITCHED ON Control word: xxxx x111
Pulse enable = 1
Quick discharge = 0
4
OPERATION ENABLED Control word: xxxx 1111
Pulse enable = 1
Quick discharge = 0
6
OPERATION DISABLED Pulse enable = 0
7
QUICK DISCHARGE ACTIVE Quick discharge = 1 (high active)
F
ERROR Error message
Reset via control word 0xxx
xxxx
or hardware input reset stored errors 0
1
NOTE!
In addition the error No. is displayed, refer to ZBM51XX
and BM53XX error detec-
tionas
from page 237.
State
driv
e manager
Meaning