BM5331 BM5331-A BM5332 BM5332-A BM5333 BM5333-A
Input rated po
wer
1) 9)
13.4 kW 22.4 kW 33.6 kW
DC link voltage (U
DC
)
1)
60 V - 760 V
DC link capacitance (internal) 330 µF 660 µF 1175 µF
DC link discharge time
(internal DC link capacitance)
240 s 480 s 900 s
Output voltage
(U
AC
)
1) 3)
0 - 500 V
Output frequency at 4 kHz
4)
0 - 450 Hz
Output rated current
(I
AC
RMS)
1) 2) 5)11)
at
4 kHz
4)
2 x 12 A 2 x 20 A 2 x 30 A
2 x 28 A with UL
Output rated current
(I
AC
RMS)
1) 2) 5)11)
at
8 kHz
4)
2 x 8.4 A 2 x 14 A 2 x 21 A
Output rated current
(I
AC
RMS)
1) 2) 5)11)
at
16 kHz
4)
2 x 4.8 A 2 x 8 A 2 x 12 A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at
4 kHz
4)
2 x 24 A 2 x 40 A 2 x 60 A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at
8 kHz
4)
2 x 16.8 A 2 x 28 A 2 x 42 A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at
16 kHz
4)
2 x 9.6 A 2 x 16 A 2 x 24 A
Short-time operation KB 200 %
Max. length of tim
e peak current
6)
Refer to ZL
oad cycle according EN61800-6as from page 75
Power loss with regard to power supply Max. 210 W Max. 310 W Max. 460 W
Power loss with regard to control voltage
supply (air-cooled)
7)
Max. 42 W Max. 55 W
Power loss with regard to control voltage
sup
ply (cold plate cooling)
7)
Max.
39 W
- Max.
39 W
- Max.
39 W
-
Current of the integrated
brake control
(option)
8)
Max. 2 x 2,0 A
Cooling air requirement power heat sink 55 m
3
/h - 55 m
3
/h - 100 m
3
/h -
Cooling air velocity power heat sink - > 5 m/s - > 5 m/s - > 5 m/s
Cooling air requirement internal space of
de
vice
10 m
3
/h - 10 m
3
/h - 10 m
3
/h -
Technical data
Instruction handbook b maXX 5000
Document No.: 5.09021.16
67
of 328
3
Footnotes refer to Zpage 73.