TAM 00609 16
DA 100 280 03 / 2015
Three phase asynchronous motor air cooled Englisch
Tests prior to commissioning 4.2
The drive is undamaged and is not located within the danger zone of other equipment
The motor is correctly aligned and fixed. All screwed connections are correctly tightened.
All the appropriate safety devices (mechanical, thermal and electrical) are mounted.
The motor connections have been carried out correctly.
The protective conductor system is correct and its functionality has been checked.
The lines and cables do not come into contact with the motor surface.
The drive does not block (release brake, if applicable).
Emergency OFF functions have been checked.
The fan has been properly connected and its functioning checked.
The direction of fan wheel rotation is identical to the identified direction of arrow.
Commissioning, operation 4.3
Notes on the brake function (if provided):
The brake is a holding brake with an emergency STOP function (power failure, emer-
gency stop)
The brake may not be used as a working brake.
The commissioning must be carried out by qualified personnel, only.
Please refer to the commisioning instructions for the converter.
Tests during commissioning:
Release brake if required.
Has the functionality of all motor modules such as the brake, encoder, cooling system been checked and
are the operating conditions observed?
Have all electrical connections been carried out and fixed as required by the regulations (refer to wiring di-
agrams)?
Have all protection measures that eliminate the possibility of contact with live parts, hot surfaces, rotating
and moving parts been observed and are these measures fully functional?
Have all output elements been mounted and set in accordance with the manufacturer’s instruc-
tions?
Was ensured that the maximum permitted speed n
max
of the motor is not exceeded? The maxi-
mum permitted speed n
max
ist the highest short-term allowable operation speed.
Tests during operation:
Watch out for unusual noises.
If scraping, scratching or grinding noises occur, stop the motor immediately and locate the cause.
Check the motor surface and connection cables for dirt, such as layers of dust, oil deposits, dampness
and leaks etc.
Check air inlet and outlet openings and any interposed filters for dirt accumulation
Check the maintenance intervals.

Other manuals for Baumuller DA 100