TAM 00609 9
DA 100 280 03 / 2015
Three phase asynchronous motor air cooled Englisch
Technical data 2.4
Designs (EN 60034-7) IM B3, IM B5 size 100 / 132 / 160)
IM B3, IM B35 size 180 / 225 / 280)
Type of protection (EN 60034-5) IP23 internally cooled, with fan
IP54 surface-cooled, with fan
Forced ventilation
DA100 Standard: Axial fan at non-drive end, built-in fan
motor
1)
;direction of air flow from drive
end to non-drive end, air outlet open
ing is axial at non-drive end
DA132 - DA 225 Standard: Axial fan at non-drive end; added-on
standard motor, direction of air flow
from drive end to non-drive end, air
outlet opening lateral, non-drive end
Option 1: Axial fan at non-drive end; built-in fan
motor
1)
direction of air flow from drive
end to non-drive end, air outlet open-
ing is lateral, non-drive end
Option 2: Radial fan at non-drive end; added-on
standard motor, direction of air flow
from non-drive end to drive end, air
outlet opening lateral drive end
DA 280 Radial fan on the non-drive end, added standard mo-
tor, air direction from non-drive end to drive-end
Air outlet opening lateral on drive end
1)
CAUTION!
Not permitted for flammable, explosive, chemically ag-
gressive or electrically well conductive dusts.
Cooling method (EN 60034-6) IP 23 IC 06 internally cooled motor
IP 54 IC 0641 surface-cooled motor
Electrical connections (refer to Appendix 1)
Main connection Terminal box
Control connection Resolver 12 pin connector, 17 pin connector at
the ENDAT interface
Fan / built-in fan motor 6-pin connector (unit DA 100)
Fan / added-on standard motor Terminal box, standard motor (unit DA 132 -280)
Brake (optional) Separate connection
Thermal sensor Connection in terminal box
Thermal motor protection (EN60034-11) Thermal sensor KTY84 in stator winding
Winding insulation (EN 60034-1) Insulation class F
Ambient temperature 0°C ... +40°C
Installation altitude (EN 60034-1) 1.000 M ASL
Storage -30 °C…+60 °C (+ 85 °C, refer to chapter 2.5)
Bearing Roller bearing with permanent lubrication (DA 100 - 225)
or with a relubricating device (DA 280) (refer to chapter
5.2)
Computed operational life 20.000 h (approximate value)
Amplitude of vibration (EN 60034-14) Level A (formerly N); optional B