EasyManua.ls Logo

Baxi 430 Combi 2 - Page 56

Baxi 430 Combi 2
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 Settings
56 Combi 2
Name
Description
Factory
value
Minimum
Maximum
Level
PP018
Minimum pump speed in heating mode [%]
85
85
100
Installer
DEAIR
Manual degassing function
Installer
CNF
Configuration CN1 and CN2
- -
Installer
AD
Searching for devices connected to the boiler PCB
- -
Installer
Tab.27 Settings table with eMO Life
Name
Description
Factory
value
Minimum
Maximum
Level
CP060
Required ambient temperature (°C) in the zone in
the holiday/antifreeze period
6
5
20 User
CP070
Maximum ambient setpoint temperature (°C) in
reduced mode that enables switching to comfort
mode with climate control (with outside sensor)
16
5
30 User
CP080
Temperature (°C) set by SLEEP activity in the zone
16
5
30
User
CP081
Temperature (°C) set by HOME activity in the zone
20
5
30
User
CP082
Temperature (°C) set by AWAY activity in the zone
6
5
30
User
CP083
Temperature (°C) set by MORNING activity in the
zone
21
5
30 User
CP084
Temperature (°C) set by EVENING activity in the
zone
22
5
30 User
CP085
Temperature (°C) set by CUSTOM activity in the
zone
20
5
30 User
CP200
Required ambient temperature (°C) for the zone in
manual mode
20
5
30 User
CP220
Reduced mode heating curve offset (with outside
sensor).
15 15 90 Installer
CP240
Adjust the effect of the room unit compared to the
outside sensor
3
0
10 Installer
CP250
Correct the temperature measured by the room unit
0
-5
+5
User
CP320
Zone operating mode
0: Scheduling
1: Manual
2: Off
0
User
CP510
Temporary room setpoint per zone
20
5
30
User
CP550
Fireplace mode
0: Disabled
1: Enabled
0
User
CP570
Timer programme selected by User
0: Program 1
1: Program 2
2: Program 3
0
User
CP730
Boost when starting zone heating: Modify the heat-
ing curve to speed up or slow down reaching of the
required comfort environment
0: Extremely slowly
1: More slowly
2: Slowly
3: Normal
4: Quickly
5: Extremely quickly
3
Installer
CP740
Building cooling speed when the heating is turned
off
0: Extremely slowly
1: Slowly
2: Normal
3: Quickly
4: Extremely quickly
2
Installer

Table of Contents

Other manuals for Baxi 430 Combi 2

Related product manuals