OPERATING YOUR FIRE
The Oxysafe flame sensing and flue blockage safety system.
For your safety, this appliance is fitted with a flue blockage safety device which will
shut down the appliance in the event of abnormal flue conditions.
This device is NOT a
substitute for an independently mounted Carbon Monoxide detector.
The device will also automatically shut off the gas supply to the fire if the pilot flame
goes out due to lack of oxygen or for any other reason.
If this device starts to repeatedly shut off the gas, get expert advice.
This device incorporates a probe which senses that the heat from the pilot flame is
correct. If this probe is cool, the device will prevent any gas flow unless the control
knob is held in at the ignition position.
If, for any reason, the flames go out when the fire is hot or if the fire is turned off when
hot, always wait at least three minutes before attempting to relight.
To light the fire.
Aspect model.
To gain access to the control knob lower the bottom front cover. To do this, support the
top and bottom of the lower front cover (See figure 2).
Amour model.
To gain access to the control knob lower the bottom front cover. To do this, hold the
knob on the bottom front cover and pull gently.
Eclipse and Fascination models.
To gain access to the control knob lower the bottom front cover. To do this, support the
top edges of the lower front cover and pull gently (See figure 3).
Landscape and Serenity models.
To gain access to the control knob lower the bottom front cover. To do this, gently push
the top of the front cover with the fingertips. The magnetic catch will release the front
cover (See figure4).
!
Depress the control knob and turn anticlockwise towards the PILOT/IGN position
(See figure 5). A spark should be generated at the pilot while turning. The spark should
ignite the pilot. The pilot flame can be seen at the left side of the fuel effect.
Page 7
OWNER GUIDE
PLEASE NOTE
When operating your fire for the first time, some vapours may be given off which may
cause a slight odour and could possibly set off any smoke alarms in the immediate
vicinity. These vapours are quite normal with new appliances. They are totally harmless
and will disappear after a few hours use.