SUPPLEMENTARY INSTRUCTIONS
FOR THE INSTALLER
27
Capacity tank l 79
Rated heat input for DHW circuit (boiler) kW
12.4
Rated heat output for DHW circuit (boiler) kW
12
kcal/h
10,320
Max. pressure of water in DHW circuit bar 8
Temperature range in DHW circuit °C 35 - 60
Heater recovery time ∆T=50 °C min
29
DHW production at discharge ∆T=30°C l/30 min
267
Production of DHW with ∆T=25°C l/min
6,9
Production of DHW with ∆T=35°C l/min
4,9
Specic ow “D” (EN 13203-1) l/min
12,7
Net weight Combi (boiler+Combi) kg
76,3
13. DISMANTLING, DISPOSAL AND RECYCLING
WARNING: only qualied technicians are authorised to service the device and system.
Before dismantling the appliance, make sure to have cut out the power supply, closed the gas inlet valve and secured all
the boiler and system connections.
Dispose of the appliance correctly according to the laws and regulations in force. The appliance and accessories cannot
be discarded along with normal household waste.
More than 90% of the materials that make up the appliance ar
e recyclable.
14. TECHNICAL SPECIFICATIONS
Boiler
79 79
24.7 34.9
24 34
20,640 29,235
8 8
35 - 60 35 - 60
12 7,5
430 570
13,8 19,5
9,8 13,9
18,6 23,6
76,3 77
1.24
1.35
1.12