ENUSER’S MANUAL BR20 | BR30
26
In reading data lock mode, if you add/remove big weight, display will sll update and lock new reading
data.
You can press and together to enter/escape animal weighing mode.
6.7. KEYBOARD LOCK
You can use keyboard lock when this funcon enable (see detail seng process in secon 7), aer keyboard
haven’t use for 10 minutes, keyboard will be lock, aer enter lock status, if you press any key, display will
show k-LCk.
If you want to escape lock mode and return work mode, hold , , key 2 seconds, display will
show ULCk, return normal mode.
6.8. SET BACKLIGHT
Hold key 3 second, display will show SEtbL, press key to enter backlight seng, press key to
change backlight mode (bL on : always on, bL AU : auto backlight, backlight will on when press any key or
add load on scale, bLoFF : backlight always o). Press key to sure, press key to scape.
6.9. SET AUTO POWER OFF
Hold key 3 second, display will show SEtbL, press key to enter.
Press key, display will show SEtoFF, press key to enter auto power o seng, press key to
change auto power o me oF on: always on, oF 5: auto power o aer standby 5 minuts, oF 15: auto
power o aer standby 15 minuts. Press key to sure, press key to scape.
7. PARAMETERS
The indicator has 3 parameters that can be programmed by the user and a parameter to do the calibra-
on.
The calibraon can be only done by the authorized technical personnel, please, if you wish do a calibraon
contact with your authorized calibraon organism who is authorized to seal and to unseal the scale.
In order to enter the calibraon parameter it is necessary to short the K2 jumper K2 of the main keyboard.
To set parameters press the key during selfchecing, display whill show Pn (ask password), press ,
, to enter.
The display will show the rst funcon, PO CHk.
Pressing the key will cycle through the other funcons.
Pressing will allow you to set the funcon. It may be necessary to either use or set a value using
the key to move the acve digit and then using the key to increment a digit, followed by the
key to enter the value. Use the key to leave a parameter unchanged.
For example when the display shows PO CHk press the key to begin.
This display will show SEt Lo, press the key to set the low limit, or press the to skip to the next
parameter, SEt H i for seng the high limit.
Aer pressing the key to set a limit, use the and keys to change the ashing digit, then use
the key to increment the ashing digit. Connue to the next digit and set it as needed.
When all digits have been set press the key to store the value. The display will go back to the parameter
just st, i.e. SEt Lo. Advanced to another prameter if needed or press the key to return to weighing.
Parameter seng table: