TP/TA User Guide 11
7 System Address
A System consists of up to eight TP/TA units that can control one ‘iVAC Pro Switch’
by means of the Program Switch. TP/TA can be assigned to work on one of four System
Addresses, A, B, C or D.
The System Address is to enable up to four systems to operate independently while within
communication range of each other.
All units required to operate as a System must be set to the same System Address.
* factory setting
8 Multi Tool Operation
The ‘iVAC Pro’ System has been designed so that up to eight TP/TA units can communi-
cate with one ‘iVAC Pro Switch’ on the same System Address.
Several TP/TA units can be in operation at the same time.
The first TP/TA unit to turn on, will turn on the ‘iVAC Pro Switch’. The last TP/TA unit to
turn off, will turn off the ‘iVAC Pro Switch’.
System Address S1 S2
A * off off
B on off
C off on
D on on