TP/TA User Guide 15
The rear Clamp Cover has three positions for mounting, to accommodate various
sizes of power cord diameter. Loosely attach the TP/TA to the cable.
1. Move the Mode Switch to the OFF position. Adjust the Sensitivity Control to
the midpoint.
2. Turn the power to your tool ON. If the TP/TA is detecting the current flow
then the Activity LED will turn on.
3. If the Activity LED does not turn on, then the Sensitivity Control should be ad-
justed counter clockwise until the Activity LED turns on.
4. If the Activity LED still does not come on, then the TP/TA should be rotated
slowly around the cable or moved along the cable until the Activity LED comes
on. At this point tighten the clamp to the cable.
5. Adjust the Sensitivity Control to a fully clockwise position. It should then be
rotated slowly counter-clockwise until the Activity LED will start to flash at a
slow rate and then increase until the Activity LED is on solid. This is the correct
setting for this power tool.
NOTE: For medium and higher Power Tools (Power Tools of more than 200
watts) the Sensitivity Control set to mid point should be fine. For lower Power
Tools the Sensitivity Control can be adjusted.