flow in the machine box. The best location of the clapboard is decided by the
air flow mode in the machine box, which can be obtained through different
location tests.
2.3.4 Power Requirements
Make sure that the power supply has nice grounding and the power at the input
side of the switch is reliable. The voltage control can be installed if necessary. At
least a 240 V, 10A fuse or a breaker is provided in the phase line if you prepare the
short-circuit prevention measures for a building.
Caution:
If the power supply system does not have good grounding, or the input power
disturbs too much and excessive pulses exist, the error code rate of communication
devices increases and even the hardware system will be damaged.
2.4 Installation Tools and Device
The tools and devices to install the S2528-B switch are not provided by the
S2528-B switch. You yourself need to prepare them. The following are the tools and
devices needed for the typical installation of the S2528-B switch: