lamp output 3 core Jack of each link.(Weld a 4/1 W,120 Ω resistor between the 2 and
3 pins.)
Important tip: the line cannot contact each other or with the metal shell.
Picture 1 DMX connection diagram
The method of calculating the initial address code of fixture:
The starting address code of the current lamp is equal to (the starting address code of
the previous lamp)+(number of channels of the lamp) stating:
1.the initial address code value of the first lamp is A001.
2.The number of basic channels for the controller shall be greater than or equal to the
total number of channels used in fixture.
3.Note: when using any controller, each lamp must have its own starting address code,
if the first lamp initial address code set A001,the lamp path number of 16; Then the
starting address code for the second lamp is set to A017; the starting address code for
the third lamp is set to A033; and so on.(this setup also needs to be determined by
different control stations)
1.6 Fixtures installation
Lamps can be placed horizontally, obliquely and upside down.Always pay attention to
the installation method when hanging obliquely and upside down.
As shown in the figure 2,To ensuring safetyBefore locating the lamps, to ensure the
stability of the installation place, In upside down installation must be Keep the lamp
don't drop the support frame,Prevent lamps from falling and sliding,need to use safety