Function Profile Description
26.XX
Pull-in safety device
CLOSE
If the pull-in safety device signals during travel, the error code E.343 appears and the door is
stopped. In the case of pull-in safety CLOSE, the CLOSE travel is blocked. Travel in the opposite dir-
ection is possible in dead-man mode. A triggered pull-in safety device is acknowledged in the CLOSE
limit position. In order to achieve Category 2 according to EN 13849-1, testing is necessary using a
switching output and the "External testing" function.
26.00 NC – normally closed | External testing
26.01 NC – normally closed | Without testing
27.XX
External switching input
If this is activated, drive commands are blocked.
27.00 NC – normally closed | Close automatically, all drive commands blocked
27.01 NO – normally open | Close automatically, all drive commands blocked
27.02 NC – normally closed | CLOSE limit position: All drive commands blocked
27.03 NO – normally open | CLOSE limit position: All drive commands blocked
27.04 NC – normally closed | CLOSE limit position: All drive commands blocked, except for the
keypad on the cover
27.05 NO – normally open | CLOSE limit position: All drive commands blocked, except for the
keypad on the cover
27.06 NC – normally closed | Keyboard on cover blocked
27.07 NO – normally open | Keyboard on cover blocked
27.08 NC – normally closed | Invisible drive commands blocked
27.09 NO – normally open | Invisible drive commands blocked
27.10 NC – normally closed | Drive commands blocked externally
27.11 NO – normally open | Drive commands blocked externally
27.12 NC – normally closed | Radio is blocked
27.13 NO – normally open | Radio is blocked
28.XX
Drive command sequence
– 3
Open / limit position /
close / open
For radio, only "Door visible = No" can be parameterised. An NO – normally open contact must be
used as the contact type.
Maintained operation
The commands are executed one after the other in the sequence OPEN / LIMIT POSITION / CLOSE /
OPEN.
Dead-man
The CLOSE command is only executed when in the OPEN or partial opening limit position. If the com-
mand is active for more than 60 s, the error code I.119 appears and the command is ignored. If the
door is visible: No, dead-man operation is not possible.
28.00
…
28.11
See drive command OPEN
29.XX
Fault display input
The input can be used to display an error of an external device (e.g. warning light).
29.00 NC – normally closed | No travel, F.850
29.01 NO – normally open | No travel, F.850
29.02 NC – normally closed | Dead-man, E.851
29.03 NO – normally open | Dead-man, E.851
29.04 NC – normally closed | Information I.852
29.05 NO – normally open | Information I.852