Changing the additional stop behaviour function with the programming unit
On delivery, the 35 diameter drive types have a reduced stop behaviour, and the 45 diameter and 58 diameter drive types have an
increased stop behaviour.
Proceed as follows to change the stop behaviour:
The "to retracted stop" limit position must be set in order to adjust the stop behaviour. The stop behaviour can be
changed during the first 3 runs towards the stop.
Press the retract button in order to retract the sun protection system.
While retracting, also press the programming button until the tubular drive switches
off automatically at the stop, and continue holding the two buttons down until con-
firmation is complete.
Confirmation is provided by one or two shifts.
1 shift = reduced stop behaviour
2 shifts = increased stop behaviour
15-en