en
Basic principles: Crucible
Recommendation: Only use BEGO crucibles
(identifiable by the BEGO logo)!
Always use crucible and inserts for the same alloy.
(Crucibles can be written on with a pencil.)
WARNING
Risk of burns due to hot parts!
Only touch the crucible handles with
safety gloves.
Grasp crucible inserts only with
tweezers.
NOTE
Crucibles of other manufacturers frequently have
incorrect dimensions. This leads to faulty casting
if the crucible opens too late or the melt leaves
the crucible too early.
Screw the handles firmly onto the crucible all the
way to the stop.
WARNING
ATTENTION
Inserts (made of graphite or glassy
carbon) require ceramic handles!
When inserts are used, the handles
become extremely hot: plastic
handles would melt!