Control 1.3 Swimming Pool Control Unit
Operation
27
- Backwashing settings (running time and backwash valve type)
- Rinsing settings (running time and rinse valve type)
- Pause for which the pump turns off so that the valves can move
- Forced filtration running time through the pool overflow channel after backwashing (select only when
the overflow pool is set)
Switching times (Setting the Backwashing)
You need to go to the Treatment Filter Cleaning Switching Times submenu to set the
backwashing switching times. A switching time for the backwashing can be set for every day of the week.
Thursday 16:00 is defined as a switching time in the basic configuration. The menu is shown in Figure 3.
Figure 3: Backwashing switching times
In field you choose the day for which the switching time applies.
In field you set the time of the individual switching time.
In field you set the repetition frequency of the individual switching time (weekly, every 2 weeks, every 4
weeks).
Trigger backwashing
You need to go to the Treatment Filter Cleaning Backwashing submenu in order to manually
trigger the backwashing. The manual backwashing is triggered by confirming the query with the Yes”
button.
Backwashing Setting
You need to go to the Treatment Filter Cleaning Backwashing Setting submenu to set the
backwashing parameters. This is shown in Figure 4.
1
2
3