K-2
VCO PITCH Calibration
Press and hold “TRIG SW” while powering up to enter the testing mode. (In this mode, the ON LED will blink yellow).
The K-2 has an internal calibration routine to calibrate the pitch of the VCO.
Press and hold “TRIG SW,” and then set the “FILTER1/2” switch. The ON LED will light yellow, indicating that the
VCO calibration has begun.
Wait until the ON LED changes color:
- Green indicates that the calibration was successful.
- Red indicates calibration failure. If this occurs, turn o the power and repeat from Step1.
Restart the unit.
End of Procedure