Synthesizers and Samplers
POLY D
OSC2/ OSC3/ OSC4 Range and Scale Calibration
Octave Range Calibration
This calibration is done after the oscillator calibration.
Turn on OSC1 VOLUME switch.
Turn all the Octave RANGE knobs to the 2' position in the OSCILLATOR BANK section.
Repeat the procedure described above for the OSC2/3/4 switches and OSC2/3/4 RANGE and SCALE trimpots.
Turn on the front panel OSC2 VOLUME switch in the MIXER section. (OSC1 is already on, OSC1 and 2 Volumes are up).