SERVICE AND CHECKS
10 HOURLY OR DAILY SERVICE AND CHECKS
Clean the end of the tube before inserting the
dipstick.
Insert the dipstick into the tube and remove to
check the fluid level.
Repeat the check procedure to verify the reading.
Hold the dipstick upright with the point pointing down-
ward when checking the oil level.
If the fluid level is on the ENGINE STOP mark (1)
the transmission may be operated until the fluid is
hot enough to perform a “Hot Check”.
If the fluid level is not on the ENGINE STOP mark,
add or drain transmission fluid as necessary to
bringittothismark.
Service Brake Accumulator Test
When any maintenance or testing is to be carried out
with the engine running the machine must still remain
in the service position as described in Service Instruc-
tions and all procedures in Procedures Before Starting
must be followed.
1. Start the engine. Wait until main pump has fully
charged the accumulators (Listen to the tone of
the engine, while charging the engine revolu-
tions will be lower).
2. Apply the service brakes repeatedly to make
the pump re-charge a few times. Discontinue
applying the brakes in a re-charge cycle while
the pump is still charging (to ensure the brakes
are not consuming oil after the pump stops, wait
4 seconds while listening to the engine. Engine
revolutions must go up after pump stops).
3. Shut down the engine.
4. Switch the ignition on and wait until the warning
lights extinguish.
5. Fully apply the service brakes and count the
number of applications before the accumulator
low pressure light illuminates. Less than two full
applications, have the system checked by
BELL EQUIPMENT service personnel.
Lubrication Checks
Auto Greasing System (Where
applicable)
Thepumpandreservoirarelocatedontheright
side of the truck below the exhaust silencer/
catalyst.
Check Grease Level
The reservoir is refilled via a grease nipple (1) on
the side of the unit.
Cab And Electrical Checks
When any maintenance or testing is to be carried out
with the engine running the machine must still remain
in the service position as described in Service Instruc-
tions and all procedures in Procedures Before Starting
must be followed.
Do not clean the cab with a pressure cleaner or a
hose pipe.
1
6
2
E
#
A
D
T
'
S
&
H
A
U
E
R
S
O
P
E
R
A
T
O
R
'
S
M
A
N
U
A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bell B40E 6X6 ADT and is the answer not in the manual?

Bell B40E 6X6 ADT Specifications

General IconGeneral
BrandBell
ModelB40E 6X6 ADT
CategoryTrucks
LanguageEnglish

Related product manuals