EasyManua.ls Logo

Belling 60DF - Technical Data

Belling 60DF
20 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TECHNICAL DATA
DUAL FUEL PRODUCTS
Data badge - Lower part of front frame
Type of gas - This cooker can be used with Natu-
ral Gas and LP Gas
Gas category - Natural Gas - II2H 3+
Pressure setting
G20 Natural Gas @ 20 mbar (set for)
G25 Natural Gas @ 25 mbar
LP GAS G30 @ 28-30 mbar
G31 @ 37mbar
Aeration - Fixed
Appliance class - Class 1, freestanding
Grill - Electric
Hob - Burners have burner heads and caps which
are removable for cleaning. Concealed electrodes
to each burner.
Electrical supply/load
220 - 240V ~ 50Hz
4000 - 4780 W
Warning: This appliance must be earthed.
Countries of destination
GB - IE - NL - FR - BE
NL GB IE FR BE
Gas Burner
Nominal Rate
G25 @ 25 mbar
Injector
Size
Nominal Rate
G20 @ 20 mbar
Injector size
Natural
Gas
Hob - small
Hob - medium
Hob - wok
Max. heat input
1.0kW
1.9kW
3.9kW
∑Qn8.80kW
77
104
152
1.0kW
2.0kW
4.0kW
77
104
152
Gas Burner NominalRatQN Injector Size
LP
Gas
G30
Hob - small
Hob - medium
Hob - wok
Max. heat input
1.0kW
2.0kW
4.0kW
∑Qn9.00kW
50
70
100
LP
Gas
G31
Hob - small
Hob - medium
Hob - wok
Max. heat input
0.9kW
1.8kW
3.6kW
∑Qn8.10kW
50
70
100
(For the Netherlands only) - This unit, category I2E, is suitable and adjusted for G + gas with a Wobbe-
index of from 43.46 to 45.3 MJ / m3 (0°C) at a nominal delivery pressure of 25mbar. The device can
be used without modications also for the appliance category E (I2E) having a Wobbe index of 47.00 –
55,7MJ / m3 (0°C) at a nominal delivery pressure of 20mbar

Related product manuals