Data badge - Lower part of front frame
Type of gas
This cooker must only be used with
Natural Gas only as specified on the appli-
ance data badge.
Gas category
Natural Gas - I
2H
Pressure setting
G20 Natural Gas @ 20 mbar
Pressure test point
Use the oven injector
Aeration - Fixed
Appliance class
Class 1, Freestanding
Countries of destination
GB - Great Britain, IE - Ireland
Grill - Grill burner is surface combustion
type. Spark gaps 3 - 4mm.
Hob - Burners have burner heads and
caps which are removable for cleaning.
Concealed electrodes to each burner.
Oven - Oven burner is sheet steel, with
pierced ports in stainless steel flame strip.
Spark Gap: 3 - 4mm. Flame supervision:
Thermoelectric type. Thermostat phial:
Front centre of oven roof.
Electrical supply
220 - 240V ~ 50Hz
Mains ignition models;
Spark generator: Mains operated 6 outlet
controlled by a single push button switch at
the LHS of the facia to individual electrodes.
Warning: This cooker must be earthed.
23
Gas Burner Nominal Injector Grammes per hour
Rate Qn Size Butane Propane
Natural Grill 2.4kW 115 - -
Gas Hob - LHF 1.0kW 77 - -
Hob - LHR & RHR 2.0kW 104 - -
Hob - RHF 3.0kW 130 - -
Oven 2.5kW 180 amal - -
Total heat input Qn 12.9kW - - -
Technical Data