AHB2 Instruction Manual Rev F Page 17
Over-Current Fault
The output current of each channel is constantly monitored. If either channel reaches an output
current of 18 Amperes, this fault is triggered and both channels are muted to protect the amplifier
and speakers. A power reset will be required.
Fault Display:
POWER light is On
Both TEMP lights are Off
Both MUTE lights are On
One or both CLIP lights are On
Typical Causes:
The load impedance of the speakers may be too low
Speaker cables may be shorted
Required Actions:
Check for shorted speaker cables
Make sure the nominal Stereo load impedance is 3 Ohms or higher
Make sure the nominal Bridged Mono load impedance is 6 Ohms or higher
Turn down the audio source
Restart the amplifier
Speaker impedance always varies with frequency. Speaker impedance may be much lower than the
rated "nominal" impedance at certain frequencies. The over-current fault detection circuits prevent
potential damage that can be caused by driving very high signal levels into very low impedances.
In STEREO mode, at full output, the 18 Amp limit can be reached if the load impedance dips below
about 2 Ohms. In MONO mode, at full output, the 18 Ampere limit can be reached if the load
impedance dips below about 4 Ohms.