AHB2 Instruction Manual Rev F Page 18
SOA Fault
The SOA (Safe Operating Area) of the output power devices is constantly monitored. If this safe
operating area is violated, both channels are muted to protect the amplifier and speakers. A power
reset will be required.
Fault Display:
POWER light is On
Both CLIP lights are On
Both TEMP lights are On
Both MUTE lights are On
Typical Causes:
The load impedance of the speakers may be too low
Speaker cables may be shorted
Amplifier has been overloaded with a high-amplitude test tone
Required Actions:
Check for shorted speaker cables
Make sure the nominal STEREO load impedance is 3 Ohms or higher
Make sure the nominal Bridged MONO load impedance is 6 Ohms or higher
Turn down the audio source
Restart the amplifier

Table of Contents