29
Use of synthetic oil does not change maintenance intervals.
DO NOT OVERFILL.
NOTE
Do not tilt the generator when adding engine oil. This could result in
overlling and damage to the engine.
Use high quality 4-stroke engine oil, certied to meet or exceed API
standard SG, SF, SAE ratings with strong detergents. Using non-
detergent or 2-stroke oil could shorten the engine’s working life.
Do not mix different engine oils.
Handle and store the engine oil with care, avoid getting dirt or dust into
the engine oil.
Before the engine oil falls below the safety margin, the low oil alert
system will automatically shut off the engine. The low oil light will turn
on.
To avoid the inconvenience of unexpected engine shutoff, check the
engine oil level as often as possible.
Max Oil Level
Min Oil Level
Oil Capacity
20 . Oz / 0.6L
Oil Cap &
Dipstick
0°C
10 20 30 40 50-10-20-30
20
32°F
40 60 80 100 120
°C
°F0-20
15W-50
10W-30
Synthetic 5W-30
5W-30
Effective Viscosity Range of Engine Oils