THRM
Triggering of the thermal switch
The control unit has switched the system to a rest status due to an excessive
number of consecutive operations. If a sufficient cooling time has elapsed, the
control unit is reset to normal operation.
In the negative, a fault in the motor might have occurred, which requires the
replacing of the motor.
DIAGNOSTICS
In the event of malfunctions, by pressing key + or - the status of all inputs (limit switches, control and safety) can be displayed. One
segment of the display is linked to each input. In the event of failure it switches on according to the following scheme.
PHO
SWC
STOP
SWO
PHC
DAS
P.P. PED
N.C. inputs are represented by the vertical segments. N.O. inputs are represented by the horizontal segments.
WASTE DISPOSAL
If the product must be dismantled, it must be disposed according to regulations in force regarding the differentiated waste disposal and
the recycling of components (metals, plastics, electric cables, etc..). For this operation it is advisable to call your installer or a specialised
company.