32
HTR
The Service Man function is enabled or disabled.
On: Service Man operation. The OPEN/CLOSE push buttons should be kept
pressed for the entire operating time.
Off: Automatic operation.
(OFF)
LTCA
During the TCA time, the blinker is enabled or disabled.
On: Enables blinker.
Off: Disables blinker.
(OFF)
Pho1
The PHOT O input is enabled or disabled in the opening phase.
On: Photocell 1 activated only in the closing phase.
Off: Photocell 1 activated in both opening and closing phases.
(OFF)
Pho2
The PHOT C input is enabled or disabled in the opening phase.
On: Photocell 1 activated only in the closing phase.
Off: Photocell 1 activated in both opening and closing phases.
(OFF)
tst1
The check on the photocell connected to PHOTO input is activated or deactivated
The test must be done after every command (PP, OPEN, CLOSE, RADIO, TCA) with
the motor not in movement and before to start the maneuver (also in case of partial
maneuver). The test is not made when the motor is already in movement, it must
stop and reverse after a safety edge or photocell intervention.
If the checks are not successful, the door/gate will not move.
On: activated check on photocell.
Off: deactivated check on photocell.
(OFF)
tst2
As for TST1, but referred to PHOTC input (OFF)
bar
Modifies the functioning mode of the inputs PHOTO (OPEN PHOTOCELL) and DAS
in case that safety edges are installed on the front and back of the leaf.
On: the input PHOTO assumes the same function of the input DAS but it reverses
the movement of the leaf only for the space set by the parameter SPIN if the safety
edge to which is connected is activated during the OPENING phase (if a CLOSE
PHOTOCELL input is given the motor stops and reverses only for 10 cm). The safety
edge connected to the DAS input is enabled only during the CLOSING PHASE.
Off: The intervention of the safety edge connected to the DAS input stops and
reverses the movement of the leaf for the space set by means of the parameter
spin (if the photocell in the opposite direction is activated, the leaf reverses only for
10cm) , both during OPENING and CLOSING phase.
The input PHOT OPEN resumes the functioning of the photocell enabled only during
the OPENING.
OFF
MINV
The opening direction of the motor is selected (see Fig. 4):
On: Right side motor mount
Off: Left side motor mount
(OFF)
NUMBER OF CYCLES (Nman)
The number of cycles (open+close) completed by the system is displayed.
When the push-button <PG> is pressed once, the first 4 digits are displayed, if the push-button is pressed once more, the last 4 dig-
its are displayed.
E.g. <PG> 0012 >>> <PG> 3456: 123.456 cycles were performed.
MAINTENANCE (maci)
This function allows to activate the indication of maintenance required after a certain number of operations, preset by the installer.
To activate and select the number of operations, proceed as follows:
Press the <PG> button, OFF is displayed, indicating that the function is disabled (default).
Select one of the numbers shown (from OFF to 100) by using the <+> and <-> keys . The figures express the value of hundreds of
cycles (e.g.: the number 50 means 5000 operations).
Press OK to activate the function. The PROG message is displayed.
When the flashing light flashes for around 10 sec at end of operation, this means that maintenance operations are needed.
RESET (RES)
RESET of the control unit. WARNING: Returns the control unit to the default values.
When the <PG> push-button is pressed once, the RES wording begins to flash, if the push-button<PG> is pressed once more, the
control unit is reset.