11
Note:
The transmitters are stored in an EPROM memory (U2), which can be removed and repositioned
in a new KER control unit, if required.
For safety reasons, it is not possible to store transmitter codes into memory during the opening/
closing phases of the motor.
LED DISGNOSTICS
The red LED indicates the activation of inputs, according to the following legend:
STOP fixed light
PHOT rapid flashing
SWO 1 flash at every 2 second interval
SWC 2 flashes at every 2 second interval
OPEN+CLOSE 3 flashes at every 2 second interval
With slow flashing, the red LED indicates that the unit is powered from the mains.
The green LED indicates the movement direction of the motor and the status of the gate according
to the following legend:
OPENING 1 flash at every 1 second interval
CLOSING 2 flashes at every 1 second interval
Open gate without TCA fixed light
Open gate with TCA rapid flashing
Closed gate LED off