Int.
Diameter
Height
Volume
40/52
292mm
300mm
0.02M
3
50/70
292mm
300mm
0.02M
3
70/90
375mm
387mm
0.04M
3
95/120
457mm
390mm
0.06M
3
125/140
457mm
390mm
0.06M
3
Table
2
Combustion
Chamber
Size
Location
The
Jetstreme 4+
must
be
located
on
a level
non-inflammable
surface
that
can
withstand
the
weight
of
the
boiler
and
associated
equipment.
The
boiler
location
must
permit
adequate
ease
of
access for
maintenance
and
servicing.
It
is
recommended
that
the
following clearances
should
be
provided:-
Above
the
boiler
600mm
(24 inches)
To
either
side
25mm
(1
inch)
In
front
900mm
(36 inches)
When
choosing
a site for
the
boiler,
the
major
consideration
is
the
provision
of
a
suitable
flue
system
and
whether
a
Conventional
type
flue
or
a Balanced Flue
type
should
be
used.
Consideration
must
be
given
to
the
required
position
of
the
flue, access of
the
oil
supply
from
the
storage
tank,
and
the
location
of
the
air
vents
that
may
be
required.
If
the
boiler
is
to
be
located
within
a
compartment
or
cupboard
then
the
compartment
or
cupboard
must
be
constructed
or
modified
for
the
purpose
intended.
Details
of
these
requirements
are
given
in
BS
6798: 1987 Specification for
the
installation of
Gas
Fired
Hot
Water Boilers
of
Rated
Input
not
exceeding 60 kW.
Conventional Flue
If
the
flue is
on
the
outside
of
the
building
then
the
flue
must
be
of
the
insulated
twin
wall
type
to
eliminate
the
possible
formation
of condensate.
The
flue
should
rise
as
near
vertically
as
possible
to
its
maximum
possible
length
before
any
bends
are
included.
The
number
of
bends
should
be
kept
to
an
absolute
maximum
of
two.
No
bend
should
have
an
angle
less
than
135°.
No
part
of
the
flue
internal
diameter
should
be
less
than
that
of
the
flue
outlet
spigot
diameter
on
the
boiler.
A
brick
chimney
should
be
lined
with
a
suitable
stainless steel flue
pipe,
or
other
suitable
non-
combustible
lining,
with
the
void
between
the
lining
and
the
masonry
filled
with
a
suitable
insulating
material
e.g. vermiculite.
The
chimney
must
always
be
swept
before
the
fitting
of
a liner.
A
draught
stabiliser
must
not
be
used
unless
the
flue
pull
is
found
to
be
excessive.
The
flue
outlet
should
terminate
at
least
600mm
(24 inches)
above
the
apex
of
the
roof, if this is
not
practical,
or
it
is
found
that
the
appliance
is
being
subjected
to
a
down
draught,
then
an
approved
cowl
should
be
fitted to
eliminate
this condition.
The
fitting
of
a
suitable
cowl is
always
recommended.
4