.A'-T--l'--"
ALL FLANGES TO THE TOP
BAFFLE CUTAWAY
SERVICING
AND
MAINTENANCE
INSTRUCTIONS
Notes
on
Servicing
The boiler
should
be serviced annually
by
a competent engineer. Failure to observe
the
correct
procedures could result
in
a
danger
to
the
user.
The cleaning
should
be
such that all residue is removed from both
the
interior
and
exterior of
the
boiler.
On
completion
of
the
interior
cleaning
the
baffles MUST
be
fitted as
per
fig
14.
If
they
are
assembled in
an
incorrect
manner
damage
may
occur
and
the
warranty
may
be
invalidated.
UPPER BAFFLE
MID BAFFLE
---/
LOWER BAFFLE
BAFFLE CONFIGURATION Fig. 14
FRONT
OF
BOILER
All
damaged
components
should
be replaced
or
made
good.
The
burner
should
be checked
and
cleaned.
The room sealing
of
the
Balanced Flue appliance MUST be maintained.
The
Burner
settings
should
be
checked
against
those
in
the
Technical Specifications in this
manual
(see figs. 8-10)
and
be
adjusted,
if
necessary,
so
that it is operating
at
its
optimum
efficiency
and
with clean combustion.
It
is recommended that the flexible oil
pipes
to the
burner
are replaced every
two
years.
21