Balanced Flue
Jetstreme 4+ boilers
are
designed
to
also
use
a Balanced Flue
system,
whereby
the
appliance
is
completely
sealed
from
the
room
where
it is installed.
Air
is
taken
directly from
the
outside
of
the
building
to
the
burner
for
combustion,
and
then
discharged
again
to
the
outside
of
the
building.
It
is
sometimes
found
that
the
burner
noise level is increased
when
passing
through
a
normal
inlet/exhaust
pipe,
but
the
Jetstreme
4+
inlet/exhaust
also
incorporates
a
silencer
to
reduce
this effect.
The flue kit
may
be
positioned so as to
pass
through
the
wall to
the
rear,
or
through
a side wall
to
the
left
or
right,
taking
due
account of
the
building
regulations
and
the
recommendations
shown
in
fig
5.
The
standard
flue kit is suitable for walls
up
to
11
inches thick. For walls
up
to 22 inches thick a
supplementary
kit is available
and
can
be
ordered
directly from Benson Heating,
quoting
Flue
Kit
No.1.
Flue
Kit
No.2.
This kit enables
the
balanced flue to
be
discharged
through
the
wall
at
a
high
level
(2
metres) above
the
floor.
Flue
Kit
No.3.
This kit,
although
still a
balanced
flue system, is suitable for situations
where
the
only
route for
the
discharge is
through
a flat
or
shallow pitched roof.
The
terminal
guard
basket
supplied
with
the
balanced
flue kit
must
always
be
fitted
even
at
high
level.
If
the
balanced
flue
terminal
discharges
within
900mm
(3
feet)
below
a
plastic
gutter
or
overhang,
the
gutter
must
be
protected
with
a non-combustible material.
Burner
Various
burners
are available for
use
on
the
Jetstreme 4+ boiler
and
all are rigorously tested for
their
suitability. Because
burners
may
be
added
to
the
range
from
time
to
time,
details
of
the
burners
are given
within
a
separate
document.
It
should
be
noted
that
the
EOGB
burner
is referred
to here; this is because
the
initial external BSRIA
approvals
for
the
Jetstreme 4+
were
carried
out
with
the
EOBG 'Burner fitted.
Oil
Supply
Any
fuel oil leak,
however
small must
be
rectified immediately.
Careful consideration
must
be
given to
the
siting of
the
oil storage tank,
taking
account of:-
Access for delivery
of
oil.
Proximity
and
relationship
of
tank
to boiler.
Visual acceptability
by
the
customer
and
neighbours.
Conformity
to local bylaws.
Building Regulations.
Protection for
the
retention
of
oil
in
the
event
of a leak.
Plastic oil storage
tanks
should
comply
with
OFS
TlOO
and
should
be
OFTEC
Approved
under
the
OFCERT Scheme.
5