SP 9.3 Winder motor
What to test:
SP 9.3 Functioning of winder motor
What to adjust: Press key 9 three times in the basic
Program
Press key 18 to confirm selected test.
Continuous running can be started or
stopped with each further pressing of key
18.
Press OK key to exit and return to basic
program.
Desired status: Press key 18 to confirm selected test.
The winder motor can be switched on or off
with each further pressing of key 18.
Press OK key to exit and return to basic
program.
Each test type is displayed in the matrix
(symbol g) until activated by pressing key
18 (start/stop). If the winder motor is
running,
'RUN' is displayed in the matrix.
Repair note:
• Check that the motor is running smoothly
and adjust mechanical parts if necessary.
• Check the winder motor connectors for
deformations. Replace if necessary.
• Check the winder motor cable for
deformation, tears or breaks. Replace if
necessary.
• Check P-Print and S-Print connectors for
deformation. Replace if necessary.
• Check P-Print and S-Print cables for
deformation, tears or breaks. Replace if
necessary.
• Check P-Print functioning. Replace if
necessary.
• Replace S-Print