19
Afterperformingallthesevisualchecks,reinstall
thebottompaneloftheovencompartmentand
proceedtosettingtheminimumforeach
burner.
STEP6:MINIMUMFLAMEADJUSTMENT
WARNING!
Theseadjustmentsshouldbemadeonlyforuse
oftheappliancewithnaturalgas.Forusewith
liquidpropanegas,
thechokescrewmustbe
fullyturnedinaclockwisedirection.
SURFACEBURNERS
1. Light one burner at a time and set the knob
totheMINIMUMposition(smallflame).
2. Removetheknob.
3. The range is equipped with a safety valve.
Using a smallsize slotted screwdriver, locate
the choke valve on the valve body and turn
the choke screw to the right or left until the
burnerflameisadjustedtodesiredminimum.
4. Make sure that the flame does not go out
when switching quickly from the MAXIMUM
totheMINIMUMposition.
OVENBURNER
1. Settheoventemperaturecontrolknobtothe
MAXIMUMsetting.
2. Closetheovendoorandoperatetheovenfor
atleast10minutes.
3. Set the knob to the MINIMUM setting
Removetheknob.
4. With a slotted screwdriver turn the choking
screw(bypass screw
at the left side of the
thermostat bar) and, while observing the
flame at the same time through the bottom
oven porthole, evaluate the consistency of
the flame so it remains on when switching
quickly from MINIMUM to MAXIMUM
setting.
Broiler burner: the broiler burner always
operates at maximum, therefore no minimum
adjustmentisrequired.