44
Problem: Morse control cable will not fit
Possible Cause Solution
Incorrect fitting: Cables are being fitted the wrong way around,
switch over and fit the opposite way.
Problem: Panel rev counter not working (when fitted)
Possible Cause Solution
No W connection to alternator: Check output from ‘W’ connection. Should be about 9V AC.
Wiring fault: Check circuit.
Problem: Battery quickly discharges
Possible Cause Solution
High load and insufficient running: Reduce load or increase charging time. Large domestic
battery banks subject to high electrical loads will take a
considerable time to recharge from a single alternator.
Low electrolyte level: Top up.
Fan belt slipping - black dust in engine compartment, Adjust tension/replace belt with a high temperature
engine compartment temperature too high: type and/or improve engine compartment ventilation.
Alternator defective: Check with dealer or service agent.
Battery defective: Replace.
Poor wiring connection: Check wiring system.