34
4.
The device displays the first measurement cycle for 3
seconds and then performs a regular measurement that
is repeated three times. In the second and third cycle, a
30-second countdown is also displayed, indicating the
time to wait until the next measurement.
To cancel the measurement, press
.
5. After the third measurement, the average measurement of
systolic pressure, diastolic pressure and pulse is displayed
and indicated with .
The cuff position control symbol
OK
is displayed through-
out the entire measurement. If the cuff is too loose,
and will be displayed. In such cases, the measure-
ment is cancelled after approx. 5 seconds and the device
switches itself off.
is displayed if the measurement could not be per-
formed properly. In this case, please refer to the “Trou-
bleshooting” section.
If necessary, re-attach the cuff after 1 minute.
The device switches off automatically after approx.
30seconds. The value is saved to the selected or most
recently used user.
6.4 Evaluating the results
General information about blood pressure
Blood pressure is the force with which the bloodstream
presses against the arterial walls. Arterial blood pressure
constantly changes in the course of a cardiac cycle.
Blood pressure is always stated in the form of two values:
- The highest pressure is the systolic blood pressure.
This occurs when the heart muscle contracts and
blood is pumped into the blood vessels.
- The lowest pressure is the diastolic blood pressure.
This occurs when the heart muscle has completely re-
laxed again and the heart is filling with blood.
Fluctuations in blood pressure are normal. Even during
repeat measurements, there may be considerable differ-
ences between the measured values. One-off or irregular
measurements therefore do not provide reliable informa-
tion about the actual blood pressure. Reliable assess-
ment is only possible when you perform the measure-
ment regularly under comparable conditions.
Cardiac arrhythmia
The device can identify heart rhythm abnormalities during
the blood pressure measurement. If is displayed after
the measurement, this indicates that an irregularity has been
detected in your pulse.
Repeat the measurement if is displayed.
When assessing your blood pressure, only use the results
that have been recorded without any irregularities in your
pulse.
Consult your doctor if
is displayed frequently. Only they
can determine, through an examination, whether there is an
abnormality.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Beurer BM 53 and is the answer not in the manual?

Beurer BM 53 Specifications

General IconGeneral
TypeAutomatic
Cuff size22 - 42 cm
Control typeButtons
Product colorGrey, White
Number of users2 user(s)
Memory registers2
Speaking function-
Placement supportedUpper arm
Mean arterial pressureYes
Display typeLED
Battery typeAA
Battery voltage1.5 V
Number of batteries supported4
Sustainability certificatesCE
Weight and Dimensions IconWeight and Dimensions
Depth140 mm
Width94 mm
Height46 mm
Weight437 g